35W Single Output Schaltnetzteil
Basisinformation
Modell: S-35
Produktbeschreibung
2. Universale AC-Eingang / Vollbereich
3. 100% Volllast-Burn-In-Test
Features: |
4. LED indicator for powr on |
|
Specification: |
Model |
S-35-5 |
S-35-9 |
S-35-12 |
S-35-15 |
S-35-24 |
|
Output |
DC voltage |
5V |
9V |
12V |
15V |
24V |
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
|
Rated current |
7A |
3.6A |
3A |
2.4A |
1.5A |
|
Current range |
0-7A |
0-3.6A |
0-3A |
0-2.4A |
0-1.5A |
|
Rated power |
35W |
32.4W |
36W |
36W |
36W |
|
Ripple & noise |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
|
DC adjustment range |
+10,-5% |
±10% |
±10% |
±10% |
±10% |
|
Setup, rise, hold time |
200ms,100ms,30ms at full load |
|||||
Input |
Voltage range |
85~132 VAC/170~264VAC 47~63 Hz;selected by switch 240~370VDC |
||||
AC current |
0.8 A/115 V 0.45A/ 230 V |
|||||
Efficiency |
70% |
72% |
76% |
78% |
78% |
|
Inrush current |
Cold start 18A/115V 36A/230V |
|||||
Leakage current |
<2mA/240VAC |
|||||
Protection |
Over load |
110%~160% |
||||
Protection type: Fold back current limiting, recovers automatically after fault condition is removed | ||||||
Environment |
Working temp. & humidity |
-10°C~+60°C;20%~90 %RH |
||||
Storage temp. & humidity |
-20°C~+85°C;10%~95 %RH |
|||||
Vibration |
10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|||||
Safety |
Withstand voltage |
I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
||||
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
|||||
Standard |
Safety standard |
Design refer to UL1012 |
||||
EMC standard |
Design refer to FCC Part15 J Conduction Class B |
|||||
Others |
Weight |
0.41Kg |
||||
Packing |
30pcs/13.4Kg/0.86CUFT |
|||||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
Produktgruppe : Schaltnetzteil